Pierce Manufacturing: Safety Recalls in 2003

Updated on March 19, 2026.

There were 3 safety recalls made by Pierce Manufacturing in 2003. See the details of the recalls below.

You can also see similar information for other manufacturers.

Data Source: NHTSA.
See this for other years:
December 15, 2003
(Campaign #: NR (Not Reported))

PIERCE/FAN HUB MOUNTING BOLTS

ON CERTAIN FIRE APPARATUS EQUIPPED WITH KENWORTH CHASSIS, CATERPILLAR C7 OR 3126E AND 2002 ENGINES, AND HORTON FAN HUBS. THE FAN HUB MOUNTING BOLTS CAN FAIL RESULTING IN THE HUB AND FAN ASSEMBLY SEPARATING FROM THE ENGINE. THE LOSS OF CLAMP LOAD CAUSES UNWANTED VIBRATION IN THE ASSEMBLY THAT LEADS TO BOLT FAILURE.
NHTSA ID: 03V524000
Component: ENGINE AND ENGINE COOLING
# of Units Affected: 9
Consequence Summary:
IF THE BOLTS FAIL, THE COMPLETE HUB AND FAN ASSEMBLY COULD SEPARATE FROM THE ENGINE RESULTING IN EQUIPMENT DAMAGE AND/OR PERSONAL INJURY.
Corrective Action:
DEALERS WILL ADD A RIGID SPACER ACROSS THE TWO LOWER MOUNTING HOLES OF THE FAN HUB TO MAINTAIN THE CLAMPING FORCE AND REPLACE ALL THE BOLTS AND WASHERS. OWNER NOTIFICATION BEGIN IN LATE DECEMBER 2003. OWNERS SHOULD CONTACT PIERCE AT 1-888-974-3723.
Park Outside Advisory: No
Do not Drive Advisory: No
October 8, 2003
(Campaign #: NR (Not Reported))

PIERCE/TIE ROD

ON CERTAIN FIRE TRUCKS WITH TANDEM STEER AXLES. THE TRW TIE-ROD ON THE REAR-MOST AXLE OF A TANDEM AXLE IS RESTRAINED FROM ROTATIONAL MOVEMENT BY A PAIR OF ANTI-ROTATION SEALS LOCATED AT THE BALL SOCKET JOINTS. THESE ANTI-ROTATION SEALS WILL COMPRESS OVER TIME. IF THE ANTI-ROTATION SEAL ALLOWS TOO MUCH MOTION, THE SEALS CAN DETERIORATE, ALLOWING CONTACT BETWEEN THE BALL SOCKET AND THE BALL SHAFT. THIS METAL-TO-METAL CONTACT WILL TRANSMIT FORCES INTO THE TIE-ROD TUBE, CAUSING FATIGUE FAILURE INITIATING AT THE ROOT OF THE FEMALE TREADS.
NHTSA ID: 03V380000
Component: STEERING
# of Units Affected: 202
Consequence Summary:
FAILURE OF THE TIE-ROD WILL ALLOW ONE OF THE WHEELS TO SWING TO THE LIMIT OF ITS STEERING STOP, POTENTIALLY CAUSING A LOSS OF VEHICLE CONTROL, INCREASING THE RISK OF A CRASH.
Corrective Action:
DEALERS WILL REPLACE THE TIE ROD. NOTIFICATION TO OWNERS BEGAN NOVEMBER 7, 2003. OWNERS SHOULD CONTACT PIERCE AT 1-888-974-3723.
Park Outside Advisory: No
Do not Drive Advisory: No
February 12, 2003
(Campaign #: NR (Not Reported))

PIERCE/HARRISON HYDRA-GEN GENERATOR PUMPS

ON CERTAIN FIRE CHASSIS EQUIPPED WITH HARRISON HYDRA-GEN GENERATORS. THE TUBING CONNECTING THE SOFT START TO THE GENERATOR PUMP CAN BREAK AWAY FROM THE FITTING AND SPRAY HYDRAULIC FLUID ONTO THE EXHAUST.
NHTSA ID: 03V043000
Component: ELECTRICAL SYSTEM
# of Units Affected: 13
Consequence Summary:
THIS CAN CAUSE A FIRE THAT COULD ENDANGER PEOPLE IN THE VICINITY, THE VEHICLE ITSELF, AND NEARBY PROPERTY.
Corrective Action:
DEALERS WILL REMOVE TWO PIECES OF STEEL TUBING AND REPLACE THEM WITH HIGH PRESSURE HOSE. OWNER NOTIFICATION IS EXPECTED TO BEGIN DURING FEBRUARY 2003. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT PIERCE AT 1-888-974-3723.
Park Outside Advisory: No
Do not Drive Advisory: No