Gillig, LLC: Safety Recalls in 2004
Updated on March 19, 2026.
There were 7 safety recalls made by Gillig, LLC in 2004. See the details of the recalls below.
You can also see similar information for other manufacturers.
Data Source: NHTSA.
December 28, 2004
(Campaign #: NR (Not Reported))
GILLIG/ARVIN-MERITOR/FRONT AXLE TIE ROD CLAMP
ON SOME BUSES, CERTAIN TIE ROD CLAMPS INSTALLED ON TIE ROD ASSEMBLIES COULD FAIL AND LEAD TO A STEERING MALFUNCTION.
NHTSA ID: 04V610000
Component: STEERING
# of Units Affected: 324
Consequence Summary:
IF BOTH CLAMPS WERE TO FAIL AND THE CROSS TUBE START TO UNSCREW, SIGNIFICANT VEHICLE MISALIGNMENT WOULD EVOLVE WITH THE POTENTIAL FOR THE TIE ROD END TO SEPARATE FROM THE CROSS TUBE, RESULTING IN LOSS OF STEERING CONTROL AND POSSIBLY RESULTING IN A VEHICLE CRASH.
Corrective Action:
ARVIN-MERITOR WILL NOTIFY GILLIG CUSTOMERS AND CONDUCT THE REMEDY AT NO CHARGE TO THE CUSTOMER. OWNERS SHOULD CONTACT ARVIN-MERITOR AT 1-248-435-1000 OR GILLIG AT 1-510-785-1500.
Park Outside Advisory: No
Do not Drive Advisory: No
October 14, 2004
(Campaign #: NR (Not Reported))
GILLIG/SURE-LOCK/WHEELCHAIR SECUREMENTS
CERTAIN GILLIG BUSES EQUIPPED WITH SURE-LOK WHEELCHAIR TIE-DOWN SECUREMENT ASSEMBLIES. THE SPROCKET TEETH OF THE RETRACTOR ASSEMBLY MAY BE OUT OF ALIGNMENT CAUSING THE LOAD PAWL NOT TO FULLY SEAT IN THE SPROCKET TEETH.
NHTSA ID: 04V500000
Component:
# of Units Affected: 242
Consequence Summary:
IN THE EVENT OF A VEHICLE CRASH, THE WHEELCHAIR MAY NOT BE ADEQUATELY SECURED POSSIBLY RESULTING IN INJURIES.
Corrective Action:
DEALERS WILL INSPECT AND REPLACE THE WHEELCHAIR SECUREMENT RETRACTORS AS NECESSARY. THE RECALL BEGAN OCTOBER 8, 2004. OWNERS SHOULD CONTACT GILLIG AT 1-800-735-1500..
Park Outside Advisory: No
Do not Drive Advisory: No
October 7, 2004
(Campaign #: NR (Not Reported))
GILLIG/CUMMINS/OIL LEAK
ON CERTAIN PHANTOM AND LOW FLOOR TRANSIT BUSES EQUIPPED WITH CUMMINS 8.3L AND 8.9L ISC AND ISL DIESEL ENGINES, OIL CAN LEAK INTO THE ENGINE COMPARTMENT FROM A CRACK IN THE CUP PLUG.
NHTSA ID: 04V485000
Component: ENGINE AND ENGINE COOLING
# of Units Affected: 149
Consequence Summary:
OIL LEAKAGE ON A HOT ENGINE CAN RESULT IN AN ENGINE COMPARTMENT FIRE, POSSIBLY RESULTING IN INJURIES.
Corrective Action:
CUMMINS WILL CONDUCT THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. CUMMINS WILL ISNTALL A STEEL CUP PLUG BOSS CAP ON THE AFFECTED ENGINES. OWNERS SHOULD CONTACT CUMMINS CUSTOMER ASSISTANCE CENTER AT 1-800-343-7357 OR GILLIG AT 510-785-1500.
Park Outside Advisory: No
Do not Drive Advisory: No
October 7, 2004
(Campaign #: NR (Not Reported))
ENGINE TURBOCHARGER/SERIES 40/DETROIT DIESEL
ON CERTAIN TRANSIT BUSES EQUIPPED WITH DETROIT DIESEL SERIES 40 ENGINES, THE TURBOCHARGER CAN FAIL ALLOWING LUBRICATING OIL TO SPILL ONTO THE ENGINE.
NHTSA ID: 04V486000
Component: ENGINE AND ENGINE COOLING
# of Units Affected: 810
Consequence Summary:
THIS CAN RESULT IN A FIRE IN THE ENGINE COMPARTMENT.
Corrective Action:
DEALERS WILL INSPECT AND REPLACE THE TURBOCHARGER TO PREVENT THE POSSIBILITY OF AN ENGINE COMPARTMENT FIRE. DETROIT DIESEL IS CONDUCTING OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. GILLIG ISSUED A RENOTIFICATION LETTER TO OWNERS ON FEBRUARY 27, 2007. OWNERS SHOULD CONTACT DETROIT DETROIT DIESEL AT 313-5923708 OR GILLIG AT 510-785-1500.
Park Outside Advisory: No
Do not Drive Advisory: No
September 24, 2004
(Campaign #: NR (Not Reported))
GILLIG/FAIL ENGINE TURBOCHARGER
ON CERTAIN TRANSIT BUSES MANUFACTURED WITH DETROIT DIESEL SERIES 50 ENGINE, THE TURBOCHARGER COMPRESSOR WHEEL CAN BREAK, RESULTING IN SHAFT IMBALANCE AND LUBRICATING OIL PASSES INTO THE EXHAUST SYSTEM.
NHTSA ID: 04V470000
Component: ENGINE AND ENGINE COOLING
# of Units Affected: 323
Consequence Summary:
THIS CAN RESULT IN AN ENGINE COMPARTMENT FIRE, POSSIBLY RESULTING IN PERSONAL INJURIES.
Corrective Action:
DETROIT DIESEL IS CONDUCTING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. DEALERS WILL INSTALL AN EXHAUST TEMPERATURE SENSOR AND REPROGRAM THE EMC CALIBRATION. GILLIG ISSUED A RENOTIFICATION LETTER TO OWNERS ON FEBRUARY 27, 2007. OWNERS SHOULD CONTACT DETROIT DIESEL AT 313-592-3708 OR GILLIG AT 510-785-1500.
Park Outside Advisory: No
Do not Drive Advisory: No
June 23, 2004
(Campaign #: NR (Not Reported))
GILLIG/HYDROGEN TRANSDUCER
CERTAIN LOW FLOOR BUSES POWERED BY A GASEOUS HYDROGEN FUEL SYSTEM. THESE TRANSDUCERS WERE MADE OF 17-4 PH STAINLESS STEEL MATERIAL WHICH MAY BE SUSCEPTIBLE TO EMBRITTLEMENT IN A HIGH-PRESSURE HYDROGEN APPLICATION ENVIRONMENT.
NHTSA ID: 04V308000
Component:
# of Units Affected: 3
Consequence Summary:
EMBRITTLEMENT COULD POTENTIALLY LEAD TO A TRANSDUCER DIAPHRAGM FAILURE.
Corrective Action:
DEALERS WILL REPLACE THE TRANSDUCER. THE RECALL BEGAN JULY 12, 2004. OWNERS SHOULD CONTACT GILLIG AT 1-510-785-1500.
Park Outside Advisory: No
Do not Drive Advisory: No
April 9, 2004
(Campaign #: NR (Not Reported))
GILLIG/CUMMINS/ECM
ON CERTAIN BUSES EQUIPPED WITH CUMMINS ELECTRONIC CONTROL MODULES ON THE C8.3G AND L10G ENGINES, THE ECM DOES NOT HAVE THE ABILITY TO DETECT A THROTTLE FAIL-SAFE ENGINE SHUTDOWN COMMAND. THIS COULD RESULT IN AN UNANTICIPATED, UNCOMMANDED OPEN THROTTLE CONDITION WITHOUT WARNING.
NHTSA ID: 04V173000
Component:
# of Units Affected: 2
Consequence Summary:
IF THIS EVENT OCCURS, THE VEHICLE OPERATOR WILL NOT HAVE CONTROL OF THE ENGINE SPEED, POSSIBLY RESULTING IN A VEHICLE CRASH.
Corrective Action:
CUMMINS WILL NOTIFY THE CUSTOMERS AND REPLACE THE ECM. OWNERS SHOULD CONTACT CUMMINS AT 1-800-343-7357 OR GILLIG AT 510-785-1500.
Park Outside Advisory: No
Do not Drive Advisory: No