Product Description:

Germ Terminator, Toothbrush Steam Sterilization for Oral Health. Model GT100. The Germ Terminator uses steam heat to sanitize two manual toothbrushes or two toothbrush heads. Water is poured into a reservoir in the device's housing. The steam cycle is followed by a drying cycle.

Product Classification:

Class II

Date Initiated: April 5, 2016
Date Posted: June 29, 2016
Recall Number: Z-2047-2016
Event ID: 74015
Reason for Recall:

CEG Enterprises, LLC is recalling Germ Terminator Toothbrush Sanitizer GT100 due to the following issues: UL label believed to be not genuine; discoloration of power cords (could indicate some degradation); reports of excessive heat.

Status: Terminated
Product Quantity: 100,548 units
Code Information:

Model GT100

Distribution Pattern:

Nationwide Distribution through Tuesday Morning retail stores.

Voluntary or Mandated:

Voluntary: Firm initiated