GE Healthcare, LLC: Medical Device Recalls in 2019
Updated on March 25, 2026.
According to to data from the FDA, there were 65 medical device recalls made by GE Healthcare, LLC in 2019. See the details of the recalls below.
You can see similar recalls for other firms.
Data Source: FDA.
- Various GE Magnetic Resonance System on-site software version Product Usage: Magnetic resonance imaging equipment for general diagnostic use
- GE Healthcare Centricity Universal Viewer Breast Imaging Centricity Universal Viewer is a device that displays medical images and data from various imaging sources, and from other healthcare information sources. Medical images and data can be displayed, communicated, stored, and processed. Typical users of this system are authorized healthcare professionals. Centricity Universal Viewer is intended to assist in the viewing, analysis, diagnostic interpretation, and sharing of images and other information.
- Aestiva 7900, Model Numbers: a) 1006-9300-000 b) 1006-9305-000 c) 1006-9118-000 d) 1006-9112-000 e) 1006-9113-000 f) 1006-9020-000 g) 1006-9033-000 h) 1006-9117-000 i) 1006-9119-000 j) 1006-9030-000 k) 1006-9032-000 l) 1006-9022-000 m) To be provided n) 1006-9120-000 o) 1006-9027-000 p) 1006-9003-000 q) 1006-9025-000
- VariCam
- Discover VH/Millennium VG Nuclear Medicine Imaging System
- Aespire 7100, Model Numbers: 1. 1009-9000-000-009469 2. 1009-9000-000 3. 1009-9000-000-013913 4. 1009-9000-000-001366 5. 1009-9000-000-009857 6. 1009-9003-000 7. 1009-9000-000-008120 8. 1009-9000-000-009600 9. 1009-9000-000-014290 10. 1009-9000-000-010585 11. 1009-9000-000-004993 12. 1009-9011-000-004795 13. 1009-9000-000-013407 14. 1009-9000-000-004604 15. 1009-9000-000-017674 16. 1009-9000-000-008763 17. 1009-9000-000-008306 18. 1009-9000-000-003277 19. 1009-9000-000-004166 20. 1009-9000-000-008560 21. 1009-9000-000-000299 22. 1009-9000-000-011444 23. 1009-9000-000-003529 24. 1009-9000-000-005666 25. 1009-9000-000-019821 26. 1009-9011-000 27. 1009-9000-000-017345 28. 1009-9000-000-009893 29. 1009-9000-000-007258 30. 1009-9000-000-004959 31. 1009-9000-000-010185 32. 1009-9000-000-016672 33. 1009-9011-000-017769 34. 1009-9000-000-014329 35. 1009-9011-000-020685 36. 1009-9000-000-026022 37. 1009-9011-000-002912 38. 1009-9000-000-014723 39. 1009-9000-000-013385 40. 1009-9000-000-006725 41. 1009-9000-000-005163 42. 1009-9000-000-004022 43. 1009-9000-000-017939 44. 1009-9000-000-000300 45. 1009-9000-000-018855 46. 1009-9000-000-016724 47. 1009-9000-000-010268 48. 1009-9000-000-011595 49. 1009-9000-000-019277 50. 1009-9011-000-023222 51. 1009-9011-000-015929 52. 1009-9000-000-017824 53. 1009-9000-000-008270 54. 1009-9000-000-010416 55. 1009-9000-000-019089 56. 1009-9000-000-013395 57. 1009-9011-000-021989 58. 1009-9000-000-000517 59. 1009-9000-000-002407 60. 1009-9000-000-008415 61. 1009-9000-000-009597 62. 1009-9000-000-010178 63. 1009-9011-000-010400 64. 1009-9011-000-011366 65. 1009-9000-000-012360 66. 1009-9101-000 67. 1009-9000-000-013787 68. 1009-9000-000-006266 69. 1009-9000-000-014915 70. 1009-9000-000-000290 71. 1009-9000-000-013507 72. 1009-9000-000-011600 73. 1009-9000-000-010595 74. 1009-9000-000-009543 75. 1009-9000-000-011111 76. 1009-9000-000-013378 77. 1009-9000-000-000526 78. 1009-9000-000-010536 79. 1009-9000-000-010116 80. 1009-9000-000-005939 81. 1009-9000-000-008216 82. 1009-9000-000-006786 83. 1009-9000-000-012155 84. 1009-9000-000-012379 85. 1009-9000-000-014000 86. 1009-9011-000-022466 87. 1009-9000-000-009912 88. 1009-9000-000-006906 89. 1009-9000-000-004380 90. 1009-9000-000-010245 91. 1009-9000-000-010413 92. 1009-9000-000-013616 93. 1009-9000-000-009428 94. 1009-9000-000-010597 95. 1009-9000-000-020606 96. 1009-9000-000-010059 97. 1009-9000-000-014122 98. 1009-9000-000-016795 99. 1009-9000-000-012149 100. 1009-9000-000-005760 101. 1009-9000-000-009836 102. 1009-9000-000-016818 103. 1009-9000-000-017699 104. 1009-9000-000-004020 105. 1009-9000-000-013953 106. 1009-9000-000-009583 107. 1009-9000-000-007938 108. 1009-9000-000-007336 109. 1009-9000-000-010435 110. 1009-9011-000-016719 111. 1009-9000-000-024098 112. 1009-9011-000-004634 113. 1009-9011-000-016794 114. 1009-9011-000-005431 115. 1009-9000-000-000598 116. 1009-9011-000-005442 117. 1009-9000-000-022792 118. 1009-9000-000-003950 119. 1009-9000-000-013921 120. 1009-9000-000-011116 121. 1009-9000-000-017203 122. 1009-9000-000-003335 123. 1009-9000-000-008264 124. 1009-9000-000-009868 125. 1009-9011-000-015245 truncated text
- Aestiva MRI, Model Numbers: a) 1006-9310-000 b) 1006-9110-000 c) 1006-9023-000 d) 1006-9028-000 e) 1006-9310-000-305077 f) 1006-9310-000-015243 g) 1006-9310-000-017602 h) 1006-9310-000-103785 I) 1006-9310-000-025109 j) 1006-9310-000-009650 k) 1006-9310-000-015224 l) 1006-9310-000-031881 m) 1006-9310-000-031854 n) 1006-9310-000-026571
- Proteus XR/a (SlOK : K993090)
- Aestiva 7100, Model Numbers: 1. 1006-9320-000 2. 1006-9321-000 3. 1006-9320-000-001101 4. 1006-9021-000 5. 1006-9012-000 6. 1006-9111-000 7. 1006-9321-000-007639 8. 1006-9321-000-000023 9. 1006-9321-000-015180 10. 1006-9320-000-010369 11. 1006-9321-000-019486 12. 1006-9321-000-007601 13. 1006-9321-000-009266 14. 1006-9321-000-008526 15. 1006-9321-000-116507 16. 1006-9321-000-009244 17. 1006-9321-000-012769 18. 1006-9320-000-004497 19. 1006-9320-000-009697 20. 1006-9320-000-014484 21. 1006-9321-000-008072 22. 1006-9321-000-007618 23. 1006-9321-000-013784 24. 1006-9320-000-010963 25. 1006-9320-000-014485 26. 1006-9320-000-008839 27. 1006-9321-000-017374 28. 1006-9321-000-014553 29. 1006-9031-000 30. 1006-9321-000-000533 31. 1006-9321-000-007785 32. 1006-9320-000-016418 33. 1006-9320-000-013302 34. 1006-9320-000-020339 35. 1006-9320-000-002141 36. 1006-9320-000-009193 37. 1006-9320-000-014443 38. 1006-9320-000-008124 39. 1006-9321-000-009347 40. 1006-9320-000-009310 41. 1006-9320-000-004623 42. 1006-9321-000-020437 43. 1006-9321-000-025830 44. 1006-9321-000-004690 45. 1006-9321-000-011348 46. 1006-9114-000 47. 1006-9322-000 48. 1006-9321-000-006678 49. 1006-9321-000-043401 50. 1006-9322-000-043399 51. 1006-9320-000-018778 52. 1006-9320-000-010161 53. 1006-9320-000-009400 54. 1006-9320-000-007948 55. 1006-9321-000-001309 56. 1006-9321-000-008305 57. 1006-9321-000-027472 58. 1006-9321-000-008643 59. 1006-9320-000-008841 60. 1006-9320-000-010102 61. 1006-9322-000-020407 62. 1006-9321-000-004831 63. 1006-9320-000-010684 64. 1006-9320-000-014654 65. 1006-9320-000-006392 66. 1006-9320-000-009056 67. 1006-9321-000-025850 68. 1006-9320-000-000473 69. 1006-9320-000-017639 70. 1006-9321-000-003110 71. 1006-9321-000-019653 72. 1006-9321-000-008529 73. 1006-9321-000-010029 74. 1006-9321-000-005790 75. 1006-9320-000-010177 76. 1006-9320-000-028131 77. 1006-9321-000-006318 78. 1006-9322-000-106884 79. 1006-9320-000-004596 80. 1006-9321-000-006645 81. 1006-9321-000-010584 82. 1006-9320-000-007779 83. 1006-9320-000-025679 84. 1006-9320-000-011509 85. 1006-9320-000-008650 86. 1006-9321-000-020045 87. 1006-9321-000-014996 88. 1006-9320-000-015449 89. 1006-9320-000-010685 90. 1006-9321-000-000266 91. 1006-9321-000-019680 92. 1006-9321-000-004778 93. 1006-9321-000-004424 94. 1006-9321-000-008747 95. 1006-9320-000-009249 96. 1006-9320-000-010834 97. 1006-9320-000-022596 98. 1006-9024-000 99. 1006-9026-000 100. 1006-9322-000-011934 101. 1006-9322-000-049412 102. 1006-9322-000-110551 103. 1006-9320-000-019424 104. 1006-9321-000-017187 105. 1006-9321-000-005997 106. 1006-9321-000-091883 107. 1006-9321-000-004524 108. 1006-9321-000-013425 109. 1006-9320-000-015413 110. 1006-9321-000-007378 111. 1006-9320-000-010661 112. 1006-9321-000-005998 113. 1006-9321-000-156642 114. 1006-9320-000-015195 115. 1006-9320-000-017086 116. 1006-9320-000-017852 117. 1006-9321-000-001974 118. 1006-9321-000-010236 119. 1006-9321-000-007641 120. 1006-9321-000-014028 121. 1006-9321-000-015552 122. 1006-9321-000-011524 123. 1006-9321-000-009297 124. 1006-9320-000-017427 125. 1006-9320-000-017498 126. 1006-9321-000-022470 127. 1006-9321-000-024751 128. 1006-9321-000-007642 129. 1006-9321-000-007636 130. 1006-9321-000-029968 131. 1006-9321-000-039161 132. 1006-9321-000-035978 133. 1006-9321-000-011702 134. 1006-9321-000-043612 models truncated
- CardioLab/ComboLab Recording Systems
- Revolution CT systems with the SmartStep Option The system is intended for head, whole body, cardiac and vascular X-ray Computed Tomography applications.
- ApexPro Telemetry Server System. Also identified as Modification To: ApexPro Telemetry System and ApexPro FH Telemetry System - Product Usage: These systems are typically deployed in sub acute care areas in hospitals or clinical sites where patient mobility can enhance the effectiveness of the medical procedures administered.
- Innova IGS 6, Interventional Fluoroscopic X-Ray System used in generating fluoroscopic and rotational images of human anatomy for cardiovascular, vascular and non-vascular, diagnostic and interventional procedures.
- Innova IGS 630, Interventional Fluoroscopic X-Ray System used in generating fluoroscopic and rotational images of human anatomy for cardiovascular, vascular and non-vascular, diagnostic and interventional procedures.
- Precision 500D The Precision 500D R&F X-ray System is intended to be used as a universal diagnostic imaging system for radiographic and fluoroscopic examinations, including general R&F and pediatric examinations.
- Centricity Universal Viewer with PACS-IW foundation 6.0, Model number 2090255-001 Product Usage: Centricity PACS-IW with Universal Viewer is a device that displays medical images (including mammograms) and data from various imaging sources. Images and data can be viewed, communicated, processed and displayed within the system or across computer networks at distributed locations. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor that offers at least 5 Megapixel resolution and meet other technical specifications reviewed and accepted by the FDA.
- GE HEALTHCARE LOGIQ P6 Premium TruScan(TM) Imagining Technology: (a) Model BT09 (b) Model BT07 Product Usage: The device is intended for use by a qualified physician for ultrasound evaluation of Fetal; Abdominal; Pediatric; Small Organ (breast, testes, thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (adult and pediatric). Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including prostate); Transrectal; Transvaginal; and Intraoperative (abdominal, thoracic, vascular).
- NM/CT 850 Product Usage: The GE NM/CT 850 system is intended for general Nuclear Medicine imaging procedures for detection of radioisotope tracer uptake in the patient body. It includes a general purpose Nuclear Medicine system using a variety of scanning modes supported by various acquisition types, and a Computed Tomography component which is intended specifically for enabling attenuation correction and anatomical localization of SPECT images.
- Discovery NM/CT 670 CZT, Model/Catalogue/Code H3906CT Product Usage: The GE Discovery NM/CT 670 CZT system is intended for general Nuclear Medicine imaging procedures for detection of radioisotope tracer uptake in the patient body. It includes a general purpose Nuclear Medicine system using a variety of scanning modes supported by various acquisition types, and a Computed Tomography system which is intended for enabling attenuation correction and anatomical localization of SPECT images and for standalone head, whole body, cardiac and vascular X-ray Computed Tomography applications.
- Prestige II, Prestige SI, Prestige VH Prestige system is a new multi-purpose conventional and digital R/F remote controlled system.
- Integrated ECG cable with 3-lead leadwires labeled as the following: 1. ECG TRUNK CABLE, 3-LD W/ INTEGRATED GRABBER LEAD WIRE, AHA, 3.6 M/12 FT; 2. ECG TRUNK CABLE, 3-LD W/ INTEGRATED GRABBER LEAD WIRE, IEC, 3.6 M/12 FT Product Usage: The reusable ECG trunk cable enables ECG monitoring with GE monitoring equipment requiring rectangular 11-pin connector cable. These accessories are indicated for use by qualified medical personnel only.
- Innova IGS 630, Angiographic X-Ray, s5i system option used in generating fluoroscopic and rotational images of human anatomy for cardiovascular, vascular and non-vascular, diagnostic and interventional procedures.
- Discovery Ml Product Usage: The systems are intended for head and whole body attenuation corrected Positron Emission Tomography (PET) imaging and localization of emission activity in patient anatomy by means of integrated PET and CT images.
- Optima PET/CT 560, 560FX Product Usage: The systems are intended for head and whole body attenuation corrected Positron Emission Tomography (PET) imaging and localization of emission activity in patient anatomy by means of integrated PET and CT images.
- Discovery PET/CT 710 Product Usage: The systems are intended for head and whole body attenuation corrected Positron Emission Tomography (PET) imaging and localization of emission activity in patient anatomy by means of integrated PET and CT images.
- Discovery NM/CT 670 ES Product Usage: The GE Discovery NM/CT 670 system is a medical tool intended for use by appropriately trained health professionals to aid in detecting, localizing, diagnosing of diseases and organ function for the evaluation of diseases, trauma, abnormalities, and disorders such as, but not limited to, cardiovascular disease, neurological disorders and cancer. The system output can also be used by the physician for staging and restaging of tumors, planning, guiding, and monitoring therapy. The GE Discovery NM/CT 670 system, combining Nuclear Medicine (NM) and Computed Tomography (CT) systems, is intended to produce: The GE Discovery NM/CT 670 system is a medical tool intended for use by appropriately trained health professionals to aid in detecting, localizing, diagnosing of diseases and organ function for the evaluation of diseases, trauma, abnormalities, and disorders such as, but not limited to, cardiovascular disease, neurological disorders and cancer. The system output can also be used by the physician for staging and restaging of tumors, planning, guiding, and monitoring therapy. The GE Discovery NM/CT 670 system, combining Nuclear Medicine (NM) and Computed Tomography (CT) systems, is intended to produce:
- Discovery Ml DR Product Usage: The systems are intended for head and whole body attenuation corrected Positron Emission Tomography (PET) imaging and localization of emission activity in patient anatomy by means of integrated PET and CT images.
- Centricity PACS Foundation Centricity PACS software product is intended for the storage, reading, diagnostic review, analysis, annotation, distribution, printing, editing, and processing of digital images and data acquired from diagnostic imaging devices.
- NM/CT 870 CZT, Model/Catalogue/Code # H3906CW Product Usage: The GE Discovery NM/CT 670 CZT system is intended for general Nuclear Medicine imaging procedures for detection of radioisotope tracer uptake in the patient body. It includes a general purpose Nuclear Medicine system using a variety of scanning modes supported by various acquisition types, and a Computed Tomography system which is intended for enabling attenuation correction and anatomical localization of SPECT images and for standalone head, whole body, cardiac and vascular X-ray Computed Tomography applications.
- NM/CT 860 Product Usage: The GE NM/CT 860 system is intended for general Nuclear Medicine imaging procedures for detection of radioisotope tracer uptake in the patient body. It includes a general purpose Nuclear Medicine system using a variety of scanning modes supported by various acquisition types, and a Computed Tomography system which is intended for enabling attenuation correction and anatomical localization of SPECT images and for standalone head, whole body and vascular X-ray Computed Tomography applications.
- NM 830 Product Usage: The Discovery NM 630 is an all-purpose dual detector nuclear imaging system intended for general nuclear medicine imaging procedures for detection of radioisotope tracer uptake in the patient body, using a variety of scanning modes supported by various acquisition types and imaging features designed to enhance image quality. The main components of the Discovery NM 630 system are: NM Gantry with Dual detector heads, patient table, Remote Control Unit and NM operation console.
- LVivo EF app on Vscan Extend. Sold under the following product names: a. Vscan Extend Dual DICOM, Model Numbers H41212ZA, H41212RN; b .Vscan Extend Dual USB, Model Number H41212RK; c. Vscan Extend Dual Wi-Fi, Model Numbers H41212YZ, H41212RL; d. Vscan Extend Sector DICOM, Model Number H41212ZD; e. Vscan Extend Sector USB, Model Number H41212RR; f. Vscan Extend Sector Wi-Fi, Model Number H41212ZC Product Usage: Vscan Extend is a general- purpose diagnostic ultrasound imaging system for use by qualified and trained healthcare professionals enabling visualization and measurement of anatomical structures and fluid. It s pocket-sized portability and simplified user interface enables integration into examination and training sessions indoors and in other environments described in the user manual. The information can be used for basic/focused assessments and adjunctively with other medical data for clinical diagnosis purposes during routine, periodic monitoring, and triage.
- Discovery NM 630 Product Usage: The Discovery NM 630 is an all-purpose dual detector nuclear imaging system intended for general nuclear medicine imaging procedures for detection of radioisotope tracer uptake in the patient body, using a variety of scanning modes supported by various acquisition types and imaging features designed to enhance image quality. The main components of the Discovery NM 630 system are: NM Gantry with Dual detector heads, patient table, Remote Control Unit and NM operation console.
- MAC VU360, Model Number 2030360-001, Electrocardiograph
- Discovery PET/CT 610 Product Usage: The systems are intended for head and whole body attenuation corrected Positron Emission Tomography (PET) imaging and localization of emission activity in patient anatomy by means of integrated PET and CT images.
- GE Senographe Pristina - Product Usage: Senographe Pristina generates digital mammographic images that can be used for screening and in the diagnosis of breast cancer. Senographe Pristina is intended to be used in the same clinical applications as traditional film-based mammographic systems.
- Discovery NM/CT 670 DR Product Usage: The GE Discovery NM/CT 670 system is a medical tool intended for use by appropriately trained health professionals to aid in detecting, localizing, diagnosing of diseases and organ function for the evaluation of diseases, trauma, abnormalities, and disorders such as, but not limited to, cardiovascular disease, neurological disorders and cancer. The system output can also be used by the physician for staging and restaging of tumors, planning, guiding, and monitoring therapy. The GE Discovery NM/CT 670 system, combining Nuclear Medicine (NM) and Computed Tomography (CT) systems, is intended to produce:
- Optima NM/CT 640 Product Usage: The GE Optima NM/CT 640 system is intended for General Nuclear Medicine imaging procedures for detection of radioisotope tracer uptake in the patient body. It includes a general purpose Nuclear Medicine (NM) system using a variety of scanning modes supported by various acquisition types, and a CT component which is intended specifically for enabling attenuation correction and anatomical localization on SPECT studies.
- Discovery IQ Product Usage: The systems are intended for head and whole body attenuation corrected Positron Emission Tomography (PET) imaging and localization of emission activity in patient anatomy by means of integrated PET and CT images.
- Revolution CT scanners Product Usage: The system is intended for head, whole body, cardiac and vascular X-ray Computed Tomography applications.
- Prestilix 1600X Prestilix system is a fully integrated remote controlled digital radiology system. It is designed for all general radiology applications with or without contract injection and interventional procedures.
- Centricity PACS-IW with Universal Viewer version 5.0, Model Number 2068177-001 Product Usage: Centricity Universal Viewer is a device that displays medical images and data from various imaging sources, and from other healthcare information sources. Medical images and data can be displayed, communicated, stored, and processed. Typical users of this system are authorized healthcare professionals. Centricity Universal Viewer is intended to assist in the viewing, analysis, diagnostic interpretation, and sharing of images and other information. Mammography images may only be interpreted using a monitor compliant with requirements of local regulations and must meet other technical specifications reviewed and accepted by the local regulatory agencies. Contraindications: Centricity Universal Viewer is contraindicated for the use of lossy compressed mammographic images. Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations.
- Silhouette VR This fully integrated system offers intuitive controls with advanced applications for maximum performance all in a space-saving design.
- Proteus XR/a The Proteus XR/a radiographic system offers the flexibility to choose a configuration based upon your specific requirements. The system provides exceptional image quality, high frequency X-ray generation, easy patient positioning, intuitive operator control and minimal system maintenance.
- NM/CT 870 DR Product Usage: The GE Discovery NM/CT 670 system is a medical tool intended for use by appropriately trained health professionals to aid in detecting, localizing, diagnosing of diseases and organ function for the evaluation of diseases, trauma, abnormalities, and disorders such as, but not limited to, cardiovascular disease, neurological disorders and cancer. The system output can also be used by the physician for staging and restaging of tumors, planning, guiding, and monitoring therapy. The GE Discovery NM/CT 670 system, combining Nuclear Medicine (NM) and Computed Tomography (CT) systems, is intended to produce
- Refurbish RIC5-9-D Probe ROHS compliant Ultrasound Probe RIC5-9-D
- Repair RIC5-9A-RS System, imaging, pulsed doppler, ultrasonic and Refurbish RIC-5-9-D REALTIME 4D
- Centricity Universal Viewer 6.0 Is a device that displays medical images and data from various imaging sources, and from other healthcare information sources.
- Giraffe OmniBed Carestation CS1 - Product Usage: The device can be operated as an incubator or as a warmer and can transition from one mode to the other on user s demand. It cannot be operated in both modes at the same time. Incubators and warmers provide heat in a controlled manner to neonates who are unable to thermo regulate based on their own physiology.
- AIR Technology Anterior Array, Catalogue Numbers: (a) 5746694, (b) 5746695, (c) 5746696, a receive-only RF coil designed for use with GE 3.0T MRI systems.
- GE Pristina Serena - Product Usage: Pristina Serena is an optional accessory of Senographe Pristina intended to provide accurate location of lesions in the breast in three dimensions.
- Achilles Insight Bone Sonometer
- Achilles Express Bone Sonometer
- Panda Infant Radiant Warmer Infant radiant warmers provide infrared heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Infant radiant warmers may be used to facilitate the neonate's transition to the external environment or to provide a controlled open environment.
- Giraffe Infant Radiant Warmer Infant radiant warmers provide infrared heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Infant radiant warmers may be used to facilitate the neonate's transition to the external environment or to provide a controlled open environment.
- Leadwire sets with snap ends: REF/Catalog Number Description 2106381-001 ECG Leadwire set, 5-lead, snap, AHA, 74 cm/ 29 in 2106381-002 ECG Leadwire set, 5-lead, snap, AHA, 130 cm/ 51 in 2106381-003 ECG Leadwire set, 5-lead, snap, IEC, 74 cm/ 29 in 2106381-004 ECG Leadwire set, 5-lead, snap, IEC, 130 cm/ 51 in 2106381-005 ECG Leadwire set, 5-lead, snap, AHA, mix 74 cm/ 29 in, 130 cm/ 51 in 2106383-001 ECG Leadwire set, 5-lead, grouped, snap, AHA, 74 cm/ 29 in 2106383-002 ECG Leadwire set, 5-lead, grouped, snap, AHA, 130 cm/ 51 in 2106383-003 ECG Leadwire set, 5-lead, grouped, snap, IEC, 74 cm/ 29 in 2106383-004 ECG Leadwire set, 5-lead, grouped, snap, IEC, 130 cm/ 51 in 2106383-005 ECG Leadwire set, 5-lead, grouped, snap, AHA, mix 74 cm/ 29 in, 130 cm/ 51 in 2106383-006 ECG Leadwire set, 5-lead, grouped, snap, IEC, mix 74 cm/ 29 in, 130 cm/ 51 in 2106385-001 ECG Leadwire set, 3-lead, snap, AHA, 74 cm/ 29 in 2106385-002 ECG LEADWIRE SET, 3-LD GROUPED, SNAP, AHA, 130 CM/ 51 IN 2106385-003 ECG LEADWIRE SET, 3-LD GROUPED, SNAP, IEC, 74 CM/ 29 IN 2106385-004 ECG LEADWIRE SET, 3-LD GROUPED, SNAP, IEC, 130 CM/ 51 IN 2106394-003 ECG Leadwire set, 5-lead V2-6, snap, AHA, 74 cm/ 29 in 2106395-001 ECG Leadwire set, 6-lead, grouped, snap, AHA, 74 cm/ 29 in 2106396-001 ECG Leadwire set, 6-lead, grouped, snap, IEC, 74 cm/ 29 in 2106396-002 ECG Leadwire set, 6-lead, grouped, snap, IEC, 130 cm/ 51 in The reusable ECG leadwire sets enable ECG monitoring with GE equipment requiring rectangular 11-pin ECG trunk cable. Use leadwire sets with ECG trunk cable or telemetry transmitter.
- Giraffe Incubator Carestation, Giraffe Incubator Carestation CS1 infant warmer
- Replacement leadwires with grabber ends: REF/Catalog Number Description 2106388-005 Replacement ECG Leadwire, grabber, BRN V, AHA, 74 cm/ 29 in 2106388-101 Replacement ECG Leadwire, grabber, LL , AHA, 130 cm/ 51 in 2106388-103 Replacement ECG Leadwire, grabber, GRN RL, AHA, 130 cm/ 2106388-107 Replacement ECG Leadwire, grabber, BLK N, IEC, 130 cm/ 51 in 2106392-004 Replacement ECG Leadwire, grabber, ORG V, AHA, 74 cm/ 29 in The reusable ECG leadwire sets enable ECG monitoring with GE equipment requiring rectangular 11-pin ECG trunk cable. Use leadwire sets with ECG trunk cable or telemetry transmitter.
- Replacement ECG leadwires with snap ends REF/Catalog Number Description 2106386-101 Replacement ECG Leadwire, snap, LL, AHA, 130 cm/ 51 in The reusable ECG leadwire sets enable ECG monitoring with GE equipment requiring rectangular 11-pin ECG trunk cable. Use leadwire sets with ECG trunk cable or telemetry transmitter.
- GE Centricity PACS-IW versions 3.6.0 through 3.7.3.9 SP1, SP2, SP3 and 3.7.3 SPa10, Model Numbers: a) 2052831-00x b) 2050578-0xx c) 2090228-002 d) 2052782-00x
- Giraffe OmniBed Carestation, Model Numbers: 2082844-001-XXXXXX; Giraffe OmniBed Carestation CS1, Model Numbers: 2082844-001-XXXXXXXX. infant warmer
- ECG Trunk Cables: REF/Catalog Number Description 2106305-001 ECG Trunk Cable, 3/5-lead, AHA, 3.6 m/12 ft. 2106305-002 ECG Trunk Cable, 3/5-lead, AHA, 1.2 m/4 ft. 2106305-003 ECG Trunk Cable, 3/5-lead, IEC, 3.6 m/12 ft. 2106305-004 ECG Trunk Cable, 3/5-lead, IEC, 1.2 m/4 ft. 2106306-001 ECG Trunk Cable, Neonatal, DIN 3-lead, AHA, 3.6 m/12 ft. 2106306-002 ECG Trunk Cable, Neonatal, DIN 3-lead, AHA, 1.2 m/4 ft. 2106306-003 ECG Trunk Cable, Neonatal, DIN 3-lead, IEC, 3.6 m/12 ft. 2106306-004 ECG Trunk Cable, Neonatal, DIN 3-lead, IEC, 1.2 m/4 ft. 2106307-001 ECG Trunk Cable, 6-lead, AHA, 3.6 m/12 ft. 2106307-002 ECG Trunk Cable, 6-lead, AHA, 1.2 m/4 ft. 2106307-003 ECG Trunk Cable, 6-lead, IEC, 3.6 m/12 ft. 2106307-004 ECG Trunk Cable, 6-lead, IEC, 1.2 m/4 ft. 2106308-001 ECG Trunk Cable, 12-lead, AHA, 3.6 m/12 ft. 2106308-002 ECG Trunk Cable, 12-lead, AHA, 1.2 m/4 ft. 2106308-003 ECG Trunk Cable, 12-lead, IEC, 3.6 m/12 ft. 2106308-004 ECG Trunk Cable, 12-lead, IEC, 1.2 m/4 ft. 2106310-001 ECG Trunk Cable, 3/5-lead w/ESU filter, AHA, 3.6 m/12 ft. 2106310-002 ECG Trunk Cable, 3/5-lead w/ESU filter, IEC, 3.6 m/12 ft. 2106311-001 ECG Trunk Cable, 3/5-lead, AHA, 6 m/20 ft. 2106311-002 ECG Trunk Cable, 3/5-lead, IEC, 6 m/20 ft. The reusable ECG trunk cable enables ECG monitoring with GE monitoring equipment requiring rectangular 11-pin connector cable.
- ECG leadwire sets: REF/Catalog Number Description 2106389-001 ECG Leadwire set, 5-lead, grouped, grabber, AHA, 74 cm/ 29 in 2106389-002 ECG Leadwire set, 5-lead, grouped, grabber, AHA, 130 cm/ 51 in 2106389-003 ECG Leadwire set, 5-lead, grouped, grabber, IEC, 74 cm/ 29 in 2106389-004 ECG Leadwire set, 5-lead, grouped, grabber, IEC, 130 cm/ 51 in 2106389-005 ECG Leadwire set, 5-lead, grouped, grabber, AHA, mix 74 cm/ 29 in, 130 cm/ 51 in 2106389-006 ECG Leadwire set, 5-lead, grouped, grabber, IEC, mix 74 cm/ 29 in, 130 cm/ 51 in 2106390-001 ECG Leadwire set, 3-lead, grabber, AHA, 74 cm/ 29 in 2106390-002 ECG Leadwire set, 3-lead, grabber, AHA, 130 cm/ 51 in 2106390-003 ECG Leadwire set, 3-lead, grabber, IEC, 74 cm/ 29 in 2106390-004 ECG Leadwire set, 3-lead, grabber, IEC, 130 cm/ 51 in 2106391-001 ECG Leadwire set, 5-lead, grabber, AHA, 74 cm/ 29 in 2106391-002 ECG Leadwire set, 5-lead, grabber, AHA, 130 cm/ 51 in 2106391-003 ECG Leadwire set, 5-lead, grabber, IEC, 74 cm/ 29 in 2106391-004 ECG Leadwire set, 5-lead, grabber, IEC, 130 cm/ 51 in 2106391-005 ECG Leadwire set, 5-lead, grabber, AHA, mix 74 cm/ 29 in, 130 cm/ 51 in 2106391-006 ECG Leadwire set, 5-lead, grabber, IEC, mix 74 cm/ 29 in, 130 cm/ 51 in 2106393-001 ECG Leadwire set, 5-lead V2-6, grabber, AHA, 130 cm/ 51 in 2106393-002 ECG Leadwire set, 5-lead C2-6, grabber, IEC, 130 cm/ 51 in 2106393-003 ECG Leadwire set, 5-lead V2-6, grabber, AHA, 74 cm/ 29 in 2106393-004 ECG Leadwire set, 5-lead C2-6, grabber, IEC, 74 cm/ 29 in 2106397-001 ECG Leadwire set, 6-lead, grouped, grabber, AHA, 74 cm/ 29 in 2106397-002 ECG Leadwire set, 6-lead, grouped, grabber, AHA, 130 cm/ 51 in 2106397-003 ECG Leadwire set, 6-lead, grouped, grabber, AHA, mix 74 cm/ 29 in, 130 cm/ 51 in 2106398-001 ECG Leadwire set, 6-lead, grouped, grabber, IEC, 74 cm/ 29 in 2106398-002 ECG Leadwire set, 6-lead, grouped, grabber, IEC, 130 cm/ 51 in The reusable ECG leadwire sets enable ECG monitoring with GE equipment requiring rectangular 11-pin ECG trunk cable. Use leadwire sets with ECG trunk cable or telemetry transmitter.
- Giraffe Incubator infant warmer
- Giraffe OmniBed infant warmer