Intuitive Surgical, Inc.: Medical Device Recalls in 2026
Updated on March 25, 2026.
According to to data from the FDA, there were 5 medical device recalls made by Intuitive Surgical, Inc. in 2026. See the details of the recalls below.
You can see similar recalls for other firms.
Data Source: FDA.
- da Vinci 5 Surgeon Console Viewer Display, ASSY, DV5 CONSOLE, IS5000, Part Number: 380730-45
- Da Vinci 5 ASSY, DV5 CONSOLE, IS5000 Model/Catalog Number: 380730 Used for minimally invasive surgery.
- Brand Name: Da Vinci Product Name: da Vinci X, Xi Surgical System, & da Vinci 5 Surgical System Model/Catalog Number: IS4000; IS4200; IS5000 Software Version: N/A Product Description: The da Vinci Xi, X, and da Vinci 5 surgical systems each consist of three main components: the Surgeon Console (SC), the Vision Cart (VC), and the Patient Cart (PC). The PC is the operative component of the system, and its primary function is to support the instrument arms and camera arm. Each system have four Universal Surgical Manipulators (USMs) also known as arms, which allow the surgeon to control up to three instruments and an endoscope simultaneously to perform surgical tasks (e.g. cutting, suturing, tissue approximation) in a variety of procedures. As the surgeon moves the hand controls within the console, the PC moves the robotic instruments within the patient in a corresponding manner. The da Vinci system and its software are designed such that instruments motion precisely tracks the motion inputs from the hand controls during surgery. Component: The affected part based on this recall, 380647-xx, USM, is a sub component of da Vinci Surgical Instrument
- Brand Name: Ion Endoluminal System Product Name: Ion Vision Probe Bag Model/Catalog Number: 490127 Software Version: N/A Product Description: The Ion Endoluminal System is a robotically assisted platform for minimally invasive peripheral lung biopsy. Ion consists of a System Cart and Controller that are used to navigate a flexible Catheter within the pulmonary tract using endoscopic visualization for diagnostic and therapeutic procedures. The Ion Fully Articulating Catheter (referred to as the Catheter) consists of the housing, sensor, input discs, shaft, tool channel, and tip. The Catheter is installed on the carriage of the arm. The Catheter is provided non-sterile and is a multi-use device. The Ion Peripheral Vision Probe (referred to as the Vision Probe or VP) is an endoscope that is compatible with, and inserted into, the Catheter tool channel. The VP provides direct visualization of the patient s airways during navigation. The VP attaches to the arm and has a collar that is rotated and then pulled to release it from the arm. The VP is provided non-sterile and is a multi-use device that can be used up to 5 times. The Vision Probe Bag (referred to as VPB) installs over the Instrument Arm for temporary storage of the VP when it is not inserted within the Catheter tool channel. The VPB is a single-use device provided sterile (folded within a pouch) by Ethylene Oxide (EO) sterilization method. Refer to HHE for additional details. Component: N/A
- da Vinci SP, SP Access Port Kit, Large Incision Reference Numbers:430073 (2.7-4cm,SP1098, Box) & 430075 (2.7-7cm,SP1098,Box)